Tape template in place, aligning the template centerline and
bottom of template with hood bottom line and with the
centerline marked on the wall.
¸%%¸¸¸
/_/F
C
D
A. Centerline
B. Lower support bracket
C. 5 x 35 mm screws
D. Mounting height reference
E. Fastener locations
F Waft
8=
Place the lower support bracket on the template aligning it
with the traced rectangle. Mark centers of 3 fastener
locations through the template to the wall.
IMPORTANT: All screws must be installed into wood.
Remove the template.
9. Drill %4" (2.75 mm) pilot holes at 2 upper locations where
screws are being installed into wood.
10. Attach the lower support bracket to the wall using
2 - 5 x 35 mm screws at location marked on the template.
B
A. Lower support bracket
B. 5 x 35 mm screws
C. Centerline on wall
Vent Cover Bracket Assembly and Installation
1. Assemble the 3 pieces of the vent cover bracket using 4 -
4 x 8 mm screws provided. The assembled bracket should be
sized to fit inside the upper vent cover.
I
/
2=
A. Vent cover bracket assembly
B. Upper vent cover
C. 4 x 8 mm screws
D. Adjustable
width
Install vent cover bracket to wall about 1/8"(3.0 mm) away
from the ceiling with 2 - 6 x 70 mm screws and 2 - 10 x 70
drywall anchors supplied.
i
i ...............................
S
I
A. Vent cover bracket
B. Centerline on wall
Complete
Preparation
1. Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
"Venting Requirements"
section.
2. Determine the required height for the 1/2"conduit and drill a
11¼"(3.2 cm) hole at this location.
3. Run the 1/2"conduit through the hole. Run wire through the
1/2"conduit according to the National Electrical Code or CSA
Standards and local codes and ordinances. There must be
enough 1/2" conduit and wires from the fused disconnect
(or
circuit breaker) box to make the connection in the hood's
electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.