Style 2: Direct Wire Strain Relief
Remove the knockout as needed for the flexible conduit
connection.
Assemble a UL listed conduit connector in the opening.
A. Removable retaining nut
B. Conduit
Tighten strain relief screw against the flexible conduit.
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire receptacle
A UL listed,
(NEMA type 14-50R)
250-volt
minimum,
40-amp, range
power supply
cord
4-wire direct
A circuit breaker
box or fused
³⁄₈"
disconnect
(1.0 cm)
5"
(12.7 cm)
3-wire receptacle
A UL listed,
(NEMA type 10-50R)
250-volt
minimum,
40-amp, range
power supply
cord
3-wire direct
A circuit breaker
box or fused
³⁄₈"
disconnect
(1.0 cm)
3"
(7.6 cm)
A
B
Go to Section:
4-wire connection:
Power supply cord
4-wire connection:
Direct wire
3-wire connection:
Power supply cord
3-wire connection:
Direct wire
4-Wire Connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Cut out and remove part of metal ground strap, as shown.
A. Metal ground strap
B. Discard.
C. Ground-link screw
2. Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
3. Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires
4. Use a Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw and ground-link section. The ground wire must be
attached first.
A
B
C
B
D