Fujitsu PRIMERGY BX900 Посібник із швидкого старту - Сторінка 17

Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Сервер Fujitsu PRIMERGY BX900. Fujitsu PRIMERGY BX900 22 сторінки. Blade server systems, fibre channel connection blade

Connecting the Embedded Switch Module to the fabric

NOTE
Refer to
"Cabling guidelines"
Before beginning the following steps, determine whether the Embedded Switch Module is in Brocade Access
Gateway or Fabric OS Native mode. This affects the configuration process.
1. If the Embedded Switch Module is in Fabric OS Native mode, continue with
Access Gateway mode, go on to
2. Log onto the Embedded Switch Module through a Telnet connection. For instructions on how to log on through a
Telnet connection, refer to
page 10.
3. Modify the domain ID, if required, using Embedded Switch Module CLI commands. Refer to the "Domain IDs"
section of the Fabric OS Administrator's Guide for more information.
NOTE
It could take a short time (typically a few seconds, but sometimes up to 20 seconds) for the newly added
Embedded Switch Module to appear in the fabric display with its newly-assigned domain ID.
4. If you need to install SFP transceivers, install them in the external Fibre Channel ports as required. The
transceivers are keyed to ensure correct orientation.
a. Ensure the transceiver is correctly oriented and, if necessary, remove the end caps from the SFP if the
transceiver does not install easily.
b. Orient the transceiver correctly and insert it into a port until it is firmly seated and the latching mechanism
clicks.
For instructions specific to the type of transceiver, refer to the transceiver manufacturer's documentation.
c.
Repeat
step a
and
NOTE
Use only Brocade-branded SFPs on the external optical ports of this module.
5. Connect the cables to the transceivers.
The cables used in trunking groups must meet specific requirements. For a list of these requirements, see the
Fabric OS Administrator's Guide.
ATTENTION
A cable should not be bent to a radius less than 5.08 cm (2 inches) under full tensile load and 3.048 cm (1.2 inches)
with no tensile load.
Tie wraps are not recommended for optical cables because they are easily overtightened.
a. Orient a cable connector so that the key (the ridge on one side of connector) aligns with the slot in the
transceiver.
b. Insert the cable into the transceiver until the latching mechanism clicks. For instructions specific to cable
type, refer to the cable manufacturer's documentation.
c.
Repeat for the remaining transceivers as required.
16 of 20
on page 4 before beginning the following procedure.
step
4.
"Using the PRIMERGY BX900 Management Blade CLI to change system settings"
step b
for the remaining ports, as required.
step 2
and
step
Brocade 5450 Embedded Switch Module QuickStart Guide
Publication Number: 53-1001265-02
3. If the Module is in
on