Kohler SV810-840 Посібник користувача - Сторінка 7
Переглянути онлайн або завантажити pdf Посібник користувача для Двигун Kohler SV810-840. Kohler SV810-840 20 сторінок. Vertical crankshaft
Також для Kohler SV810-840: Посібник користувача (21 сторінок), Посібник користувача (21 сторінок)
Refer t otheoperating instructions o ftheequipment
thisengine powers. Because of equipment design or
application, theremaybemorestringent r estrictions
regarding theangleofoperation.
NOTE: Donot operate t hisengine continuously
atangles e xceeding 2 5 ° in anydirection.
Engine damage couldresult f rominsufficient
lubrication.
Cooling
NOTE:
If debris builds up on tile grass screen or other
cooling areas, stop the engine immediately
and clean. Operating
the engine with blocked
or dirty air intake and cooling areas can cause
extensive
damage due to overheating.
See
Clean Air Intake/Cooling
Area.
WARNING:
Hot Parts!
Engine components can get extremely hot from operation.
To prevent severe burns, do not touch these areas while
the engine is running, or immediately after it is turned
off Never operate the engine with heat shields or guards
removed.
Engine Speed
NOTE:
Do not tamper with the governor
setting
to increase
the maximum
engine speed.
Overspeed
is hazardous
and will void the
engine warranty.
Tile maximum
allowable
high idle speed for these engines is 3675 RPM,
no load.
Maintenance
instructions
Maintenance,
repair, or replacement
of the emission
control
devices and systems,
which are being done at the
customers
expense,
may be performed
by any non-road
engine
repair establishment
or individual.
Warranty
repairs
must be performed
by an authorized
Kohler service outlet.
_
WARNING: Accidental
Starts!
Disabling
engine.
Accidental
starting
can cause severe injury
or death. Before working
on the engine or
equipment,
disable the engine as follows: 1) Disconnect
the spark plug lead(s). 2) Disconnect
negative
(-) battery
cable from battery.
Maintenance
Schedule
These required
maintenance
procedures
should be performed
at the frequency
stated in tile table. They should
also be included
as part of any seasonal
tune-up.
Frequency
Maintenance
Required
*
Fill fuel tank.
Daily Or Before
•
Check oillevel.
Starting Engine
•
Check air cleaner for dirty _,loose, or damaged
parts.
*
Check air intake and cooling areas, clean as necessaryL
Every 25 Hours
*
Service precleaner
elementL
Every 50 Hours
*
Check air cleaner element,
clean or replace as necessary _.
*
Replace air cleaner element
and precteanerL
*
Change
oil and oil filter (more frequently
under severe conditions).
Annually
or
*
Remove cooling shrouds
and clean cooling areas _.
Every 100 Hours
*
Replace fuel filter.
*
Check spark plug condition
and gap.
Every 200 Hours
*
Have valve lash checked/adjusted
2.
*
Have bendix starter drive serviced 2.
Every 500 Hours
*
Have solenoid
shift starter disassembled
and cleaned 2.
_Perform
these maintenance
procedures
more fl_equently
under
extremely
dusty,
dirty conditions.
2Have a Kohler
Engine
Service
Dealer perform
these services.
Check Oil Level
The importance
of checking and maintaining
the proper
oil level in the crankcase
cannot be
overemphasized.
Check oil BEFORE EACH USE as
follows:
.
2.
Make sure the engine is stopped,
level, and is cool
so the oil has had time to drain into the sump.
Clean the area around
and the underside
of the
oil fill cap/dipstick
before removing
it. This will
help keep dirt, debris, and other foreign matter
out of the engine.