• Knob: The user can turn the knob to select the temperature. The temperature value will be according to
[normal temperature] (inlet water temperature value)—>[ 45°C ]—>[ 50°C ]—>[ 55°C ]—>[ 60°C ]—>[ 65°C]
—>[ 70°C ]—>[ 75°C ]-->[ 80°C ]—>[ 85°C ]—>[ 90°C ]—>[ 100°C ]—>[ CO ] (cold water) for sequential
cycles, and the corresponding selection will be shown on the display panel. Each time the temperature is
selected, the buzzer emits a short "ding" sound. The display panel will show the last setting status at standby
mode; if the appliance power reconnected, it will restore the factory settings to the [normal temperature]
stage.
• Water Extraction Key: In the unlocked state, touch the water extraction key [
temperature, the appliance dispenses water according to the selected water temperature and water volume,
the corresponding function key will light up in white when dispensing water, and the panel will display the
corresponding water temperature and water volume icon. After dispensed, the water extraction key light will
off. The user can touch the water key [
] to stop the operation, and touch the water extraction key [
again to dispense water according to the selected water temperature and water volume
Reminder: Each time the function key is touched, the buzzer emits a short "ding" sound.
• Refrigeration Indicator: When the refrigeration indicator shows on the display panel, it indicates the
appliance at refrigeration state; after completed, the refrigeration icon will light off.
• Antibacterial Function: When starting to dispense water, UVC-LED to sterilize the water in the pipeline
automatically, turns on the white LED indicator lamp, and displays the "UV" indictor on the display panel at
the same time. After that, the white LED indicator lamp and the "UV" indicator light will off.
Water Shortage Reminder
When the system detects that the water level has reached the lowest water level, the appliance will start the
water shortage protection automatically; at this time, the water pump and heating body will stop the operation,
the water shortage indicator on the display panel will flash and the buzzer will sound 5 times.
After filling the water, tap the water button [
] at the unlocked state, the water pump will detect the water
level again and the water shortage indicator on the display panel will light off. After completion, the product will
resume normal operation.
CAUTION! After dispensed, user must wait until no remaining water discharge before taking out the cup,
otherwise, you may be scalded by the remaining water.
Reminder
1.
If the water tank is out of water during operation, no water will discharge while warning signal emits. To
resume, add sufficient water to the water tank.
Attention! If there is remaining water, it is recommended to clean up first to avoid overflow.
2.
During heating and refrigeration, there will be slight noise come out from the product and the pump, this
is normal situation.
3.
The boiling time varies due to ambient and water temperature. (The boiling time will be extended if the
water temperature is low).
8
Your Partner in Cool.
] after selecting the
] once

TROUBLESHOOTING

Check the following before calling for servicing.
Symptoms
Checking Points
The product cannot
Check if the dispenser is well
switch on
connected with power supply.
Loose internal connections/parts.
Button does not
The appliance is in a locked
respond
state.
Circuit control failure.
Cannot extract
Too much scale or impurities in
water
the appliance.
The hot water
Too much scale or impurities in
temperature is not
the appliance.
high enough
Abnormal circuit control function.
Abnormal power supply voltage.
Error Code El
Heating element overheats.
Error Code E2
The inlet water temperature
exceeds 40°C.
Error Code E3
Outlet water temperature sensor
failure.
Error Code E4
Water inlet temperature sensor
failure.
If the above remedies / solutions cannot fix the problem, unplug the appliance immediately, note the error code
and report it to Aqua Cooler for checking and repairing. To avoid any danger and damage to the appliance, do
not disassemble or repair it by yourself.
Remedy
Check if the dispenser is well connected with
power supply.
Check if the power switch is turned on.
Contact Aqua Cooler for servicing.
Touch child lock key to unlock.
Contact Aqua Cooler for servicing.
Descale (refer to Cleaning and Storage for
details).
Check the water tank inlet.
Descale (refer to Cleaning and Storage for
details).
Contact Aqua Cooler for servicing.
Check whether there is enough water in the
water tank and the water inlet.
Contact Aqua Cooler for servicing.
Check the temperature of the water tank or
the inlet water.
Contact Aqua Cooler for servicing.
Contact Aqua Cooler for servicing.