Installation requirements.
XL, XT, XR.
Components for Billi B-4000
– XL, XT, XR
Before commencing installation,
ensure you have identified the following.
1. Underbench module
2. Dispenser upper with tubing
3. Dispenser base & mount
4. Barb locking bush
5. 4mm chrome screw & allen key
6. Large washer
7. Tube spring clamps x 3
8. 600mm flexible braided hose
9. Filter cartridge (installed)
10. User guide
11 Warranty registration card
12. Warning label
Additional Components – XR
13. Remote panel kit
Determine Unit Location
Plan the installation. Dispenser tube lengths,
position of power and water outlets, required
air space around the underbench module and
access for service must be considered before
cutting tube lengths. Refer to Diagrams 1 and 2.
Unit must be installed horizontally with display
panel facing to front of cupboard. The B-4000 is
designed for internal installation only.
Model
Height
Width
B-4000
340mm 180mm 365mm 10mm
Water Supply
The B-4000 must only be connected to a cold
water supply. A ½" BSP stop tap (not supplied)
is to be installed in an easily accessible position
within 600mm from the B-4000 water
supply inlet.
Dynamic water supply pressure:
Min. 250 kPa, max. 1000 kPa.
Minimum water supply: 6 l/m at 250 kPa
Supply temp: min. 5°C, max. 30°C.
* Where supply pressure is greater than 500
kPa a PLV must be fitted. Billi recommends
PLV's with anti-hammer properties.
Do not install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
2
Power Requirements
A single 10 amp standard power outlet
is required. A dedicated circuit should be
provided and must be fitted with an earth
leakage protection device (RCD). An externally
fitted RCD device is acceptable. The B-4000 is
supplied with a 1 metre flex cord and plug.
Min side
Depth
clearance
20mm
180mm
340mm
FRONT
Tubing
Power
removed
Outlet
for clarity
Cupboard Dimensions:
230mm Minimum Width
523mm Minimum Depth
Stop Tap
(Installed by Plumber)
Max 600mm from Unit
20mm
175mm
215mm
10mm
bench
thickness
1mm-48mm
35mm
Tubing
removed
for clarity
20mm
460mm
340mm
SIDE
460mm
180mm
TOP
800mm
60mm
Tube Length
Minimum
Supplied
Clearance
Diagram 1
130mm
70mm
Diagram 2
Diagram 3