Maintenance (continued)
Hazardous suction can trap hair or body parts, causing severe injury or death. Do not block suction.
DANGER:
B. Remove the ring and cover assembly by turning counterclockwise. If necessary, tap handles gently with a rubber mallet.
C. Remove the basket and clean. Inspect holes in the basket for blockage. Clean the basket with water and replace in the basket housing.
Do not hit the basket to clean. Verify the basket is oriented correctly in the housing.
D. Clean and inspect the lid O-ring. Reinstall ring and cover assembly.
E. Prime the pump (see priming instructions).
DRAINING THE PUMP
DANGER: Risk of electric shock . Can shock, burn or kill. Disconnect power before working on pump or motor
1. Pump down water level below all inlets to the pool. Risk of electric shock . Can shock, burn or kill. To avoid dangerous or fatal electrical
shock hazard, turn OFF power to motor before draining pump.
2. Remove trap cover and use low pressure air to blow accumulated water from the piping system. Never use high pressure air to purge
system.
3. Cap inlet piping after draining to keep water out of the pipes.
4. To prevent pump from freezing, remove trap cover and drain the tank body through the two drain plugs provided. Clean pump thoroughly;
replace trap cover.
DRAIN
PLUGS
Figure 11 - DV FLO Pump Drain Plugs
Tighten trap cover by hand only (no wrenches)! If pump is not anchored, use caution to avoid breaking attached piping
NOTE:
5. Be sure motor is kept dry and covered.
DRAIN
PLUGS
Figure 12 - APEX Series Pump Drain Plugs
12
.
.