Patch 54266-02
Patch 54266-02
C613-10417-00 Rev B
PCR: 40537
Module: BGP
When the status of an interface changed, the BGP revaluation of IP routes
for redistribution (via the add bgp import or add bgp network commands)
was incorrect. This gave inconsistent BGP route tables depending on the
order of events. This issue has been resolved.
PCR: 40549
Module: SWI
The receipt of two IP packets whose destination IP addresses were subnet
addresses caused the router to reboot. This issue has been resolved.
PCR: 40560
Module: DHCP
A router reboot could occur when the DHCP server checked whether an IP
address was being used by other hosts, for example, after processing a
DHCP Discover message. This issue occurred if probe=arp was specified
for the DHCP range, and if DHCP had been disabled and then enabled. This
issue has now been resolved.
PCR: 40573
Module: LOG
If the log module was configured to store a very large number of messages
(for example, more than 3000 messages), a watchdog timeout could occur
when the show debug command was executed. This issue has been
resolved.
PCR: 40587
Module: IPG, PIM, DVMRP
When doing Layer 3 IP multicast routing, the router would flood traffic to
all ports in the downstream VLAN. This issue has been resolved, and now
the router will do the portmap calculation based on IGMP, PIM-SM, PIM-
DM, DVMRP neighbour information, and forward the multicast traffic to
the calculated portmap.
PCR: 40588
Module: PPP, CC
A toplogy change in a network could cause a router to attempt to activate
an ISDN call configured with direction=in when the call was already
activated. In this situation, the call was failing, and the PPP link over the call
would not come open. This issue has now been resolved.
PCR: 40592
Module: BOOTP
If a timed-out ARP entry was renewed by BOOTP, the new entry be created
with no port association. This issue has been resolved.
PCR: 40599
Module: FIREWALL
The add firewall apprule command did not correctly accept the port
parameter, so the port value was set to zero. This issue has been resolved,
and the port value is stored correctly.
PCR: 40612
Module: IPG, DNS Relay
There was an issue in DNS Relay that resulted in a memory leak. The leak
occurred when a response to a relayed DNS request contained an
authoritative nameserver or additional information and the DNS request
was forwarded to one of those servers. There was also an issue whereby
DNS queries handled by DNS Relay would sometime result is corrupt
entries in the DNS cache. These issues have been resolved.