Dell PowerEdge E31S Series Посібник користувача - Сторінка 13

Переглянути онлайн або завантажити pdf Посібник користувача для Сервер Dell PowerEdge E31S Series. Dell PowerEdge E31S Series 32 сторінки.

Dell PowerEdge E31S Series Посібник користувача
Figure 6. AC PSU status indicator
1
AC PSU status indicator/handle
Table 6. AC PSU status indicators
Convention
Power indicator
pattern
A
Green
B
Flashing green
C
Flashing green and
turns off
D
Flashing amber
E
Not lit
Condition
A valid power source is connected to the PSU and the PSU is operational.
When the firmware of the PSU is being updated, the PSU handle flashes green.
When hot-adding a PSU, the PSU handle flashes green five times at 4 Hz rate and turns
off. This indicates a PSU mismatch with respect to efficiency, feature set, health status,
and supported voltage.
NOTE:
Ensure that both the PSUs are of the same capacity.
CAUTION:
For AC PSUs, use only PSUs with the Extended Power Performance
(EPP) label on the back.
Indicates a problem with the PSU.
CAUTION:
When correcting a PSU mismatch, replace only the PSU with the
flashing indicator. Swapping the PSU to make a matched pair can result in an
error condition and unexpected appliance shutdown. To change from a high
output configuration to a low output configuration or vice versa, you must turn
off the appliance.
CAUTION:
If two PSUs are used, they must be of the same type and have the
same maximum output power.
CAUTION:
Combining AC and DC PSUs is not supported and triggers a
mismatch.
Power is not connected.
Overview
13