Dell PowerEdge E31S Series Посібник користувача - Сторінка 14

Переглянути онлайн або завантажити pdf Посібник користувача для Сервер Dell PowerEdge E31S Series. Dell PowerEdge E31S Series 32 сторінки.

Dell PowerEdge E31S Series Посібник користувача
Figure 7. DC PSU status indicator
1
DC PSU status indicator
Table 7. DC PSU status indicators
Convention
Power indicator pattern
A
Green
B
Flashing green
C
Flashing amber
D
Not lit

iDRAC Direct LED indicator codes

The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC subsystem.
NOTE:
The iDRAC Direct LED indicator does not turn on when the USB port is used in the USB mode.
14
Overview
Condition
A valid power source is connected to the PSU and that the PSU is operational.
When hot-adding a PSU, the PSU indicator flashes green. This indicates that there is a
PSU mismatch with respect to efficiency, feature set, health status, and supported
voltage. Ensure that both the PSUs are of the same capacity.
Indicates a problem with the PSU.
CAUTION:
When correcting a PSU mismatch, replace only the PSU with the
flashing indicator. Swapping the PSU to make a matched pair can result in an
error condition and unexpected appliance shutdown. To change from a High
Output configuration to a Low Output configuration or vice versa, you must
turn off the appliance.
CAUTION:
If two PSU are used, they must be of the same type and have the
same maximum output power.
CAUTION:
Combining AC and DC PSU is not supported and triggers a
mismatch.
Power is not connected.