Removing the bezel assembly
Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION:
To prevent damage to the storage sled locks, use a #2 Phillips screwdriver to turn the sled locks to lock or unlock
positions.
NOTE:
This is a field replaceable unit (FRU). Removal and installation procedures must be performed only by Dell certified
service technicians.
NOTE:
You must remove the bezel assembly to replace a faulty bezel assembly or when you are replacing the chassis.
1
Ensure that you read the
2
Follow the procedure listed in
3
Remove the Mini Enterprise Service Tag (MEST) and save for future use.
4
Keep tweezers ready for the service caution label.
5
Keep the #2 Phillips screwdriver ready.
Steps
1
Release the service caution label from top of the storage sled by using tweezers.
2
Remove the service caution label and save for future use.
Figure 29. Removing and installing the service caution label
1
service caution label
3
Using a Phillips #2 screwdriver, turn the sled locks to lock position.
4
Pull the drive drawer handle and open the drive drawer.