Switch configuration (OS 10.x)
3.1.7
Enable switch ports
Switch ports are enabled and are configured for switchport mode access by default for S4048 switches. If
choosing to reconfigure the ports, use the following steps.
Option 1: Enable ports individually by entering the port number.
OS10# configure terminal
OS10(config)#interface ethernet 1/1/1
Note: For ports configured as 4 x 10GbE breakout ports, use the following command in which 1/1 represents
the switch number, <xx> represents the port number, and <yy> represents sub port number:
OS10(conf)#interface range ethernet 1/1/<xx>:<yy>
OS10(conf-if-eth1/1/1)# switchport mode access
OS10(conf-if-eth1/1/1)# no shutdown
OS10(conf-if-eth1/1/1)# exit
Option 2: Enable multiple ports at once using the range parameter.
OS10# configure terminal
OS10(config)# interface range ethernet 1/1/1–1/1/48
Note: For ports configured as 4 x 10GbE breakout ports, use the following command in which 1/1 represents
the switch number, <xx> represents the port number, and <yy> represents sub port number:
OS10(conf)#interface range ethernet 1/1/<xx>:<yy>-1/1/<xx>:<yy>
OS10(conf-range-eth1/1/1-1/1/48)# switchport
OS10(conf-range-eth1/1/1-1/1/48)# no shutdown
OS10(conf-range-eth1/1/1-1/1/48)# exit
3.1.8
iSCSI enable
This section describes enabling iSCSI auto-detection of attached storage arrays and switch auto-
configuration. PS Series and Dell EMC SC Series storage arrays will be detected by the switch when iscsi is
enabled. The switch will auto-configure for Jumbo frames with MTU 9216 and flowcontrol receive on, transmit
off for all the ports. The ports detected to be connected to the above storage units will be auto-configured as
spanning-tree edge ports and unicast storm control is disabled.
OS10(config)# iscsi enable
OS10(config)# iscsi session-monitoring enable
20