Allmatic SCOR.AS Посібник - Сторінка 5
Переглянути онлайн або завантажити pdf Посібник для Блок управління Allmatic SCOR.AS. Allmatic SCOR.AS 8 сторінок. For barriers bevk 1 motor 24vcc
11. Personalization of pedestrian opening (partial opening)
This procedure must ONLY be carried out by the installer and ONLY during the put in function of the system. For a correct programming, before
carrying out any modification, bring always back the door to the totally closed position. If it is not personalized, the pedestrian opening
corresponds to the total opening of the automation.
Dipswitch Position
1
Press and release the 1° memorized key or
2
the RED key (P1)
When the automation has reached the
desired open position, press and release
3
again the 1° memorized key or the RED key
(P1)
Once close the gate, the flashing light blinks 4
4
times.
Dipswitch Position
5
12. Personalization of the slowing down phase
This procedure must ONLY be carried out by the installer and ONLY during the put in function of the system. For a correct programming, before
carrying out any modification, bring always back the door to the totally close position. If the pedestrian opening is not personalized, it corresponds
to the total opening of the automation. During the learning phase it is possible to decide where the automation must start the slowing down phase.
Dipswitch Position
1
Press and release the 1° memorized key or the RED k ey
2
(P1)
Once the automation reaches the starting desired position
of slowing down, press and release again the 1°
3
memorized key or the RED key (P1).
Once the automation reaches the position of completely
4
open it recloses itself automatically
Once the automation reaches the starting desired position
of slowing down, press and release again the 1°
5
memorized key or the RED key (P1).
PLEASE NOTE: if no slowing down areas are defined, the control unit will set the factory settings.
Once the automation reaches the position of completely
6
closed, the flashing light blinks 4 times
Dipswitch Position
7
PLEASE NOTE: it is indispensable, after setting the desired velocity on slowing down, to carry out
a new programming of the stroke in case in which the slowing down phase is personalized.
6-1622381
rev.2
04/02/2016
The flashing light starts
to blink lightly
The automation starts to open.
The automation stops and after some
second recloses itself automatically
The learning has had a successful conclusion
The learning is ended. The control unit is ready
to regularly work
The flashing light starts
to blink lightly.
The learning is ended. The control unit is
ready to regularly work.
ITA
ENG
FRA
ESP
DEU
The automation
starts to open.
The automation pass to the slowing down on opening
The automation recloses itself.
The automation pass to the slowing down on closing
The learning has had a successful end
POR
.
Pag 5 di 8