• Put the shutoff all the way
into the neck of the bowl
(e.g. bottle, fig. 12a), or a
vessel wall (e.g. pot, fig.
12b).
• Make sure that the shutoff
is securely latched (fig.
13a, 13b).
• Insert the tip into the hole
of the shutoff (fig. 14a).
• Wait for the bowl to fill
with clean water before
the automatic shutting off
of the water supply and
disconnecting the tip.
• Disconnect the shutoff from the bowl.
• If you want to stop filling the bowl ahead the schedule, click on the button at the end of the shutoff (fig. 14b).
8. SYSTEM MAINTENANCE
The service life of the membrane module is directly dependent on the performance of the water
treatment unit. Therefore, it is very important to replace the filter modules on time.
To replace the K5 plug-in module:
• Close the inlet tap and connect the nozzle to the storage tank to relieve the pressure.
• Pressing the lock button fully in this position, turn the used filter module clockwise and remove it.
• Remove the packaging film from the new module;
• Insert the new module into the collector block until it stops and, lightly pressing, turn the module clockwise
until it clicks.
• Open the inlet tap and make sure the RO is tight.
• Insert the assembled module into the collector block until it stops and, while slightly pressing, turn the
module clockwise until it clicks.
• Open the inlet tap and make sure the RO is tight.
To replace the K2 plug-in module:
• Close the inlet tap and connect the nozzle to the storage tank to relieve the pressure.
• Pressing the lock button fully in this position, turn the used filter module clockwise and remove it.
• Remove the packaging film from the new module.
• Insert the new module into the collector block until it stops and, while lightly pressing, turn the module
clockwise until it clicks.
• Open the inlet tap and make sure the RO is tight.
• Insert the assembled module into the collector block until it stops and, while slightly pressing, turn the
module clockwise until it clicks.
• Open the inlet tap and make sure the RO is tight.
To replace the K2 plug-in module:
• Close the inlet tap and connect the nozzle to the storage tank to relieve the pressure.
• Pressing the lock button fully in this position, turn the used filter module clockwise and remove it.
• Remove the packaging film from the new module.
• Place the modules in the "flush" position (see fig. 9 "The position of the modules in the RO").
• Open the inlet tap.
8
Figure 11a