AquaPower AP40RP Посібник користувача - Сторінка 9

Переглянути онлайн або завантажити pdf Посібник користувача для Фільтр для басейну AquaPower AP40RP. AquaPower AP40RP 16 сторінок. Aquapower salt water chlorinator

Above Ground Installation Instructions
You're above ground AquaPower-Plus Salt Water Chlorinator requires
very little installation and should not require professional installation.
If however you do want professional installation please contact us for
assistance.
Without optional A-Frame Stand.
1. Remove unit and electrode from box.
2. If you have not purchased the optional stand than you must
mount your power pack in a suitable location (fence, post, block
wall, etc.) in close proximity to your existing pool equipment.
3. Mount the mounting bracket in appropriate location using the
supplied screws and anchors.
4. After hanging the power box. You may proceed to the cell
installation.
5. You may either run pvc piping to cell or use your existing
plastic hoses.
6. Your cell must be installed after your pool heater or filter.
(The last component before water enters your pool)
7. After cell is plumbed in refer to wiring instructions in your manual.
With optional A-Frame Stand
1. Remove unit and electrode from box.
2. Set up stand as with stand instructions.
3. Hang the power box on the hanging bracket included with the
AquaPower-Plus unit.
4. Set the cell on the u-brackets below the power box.
5. Turn off your valves to your pool equipment or plug openings in
side of pool so water will not discharge during installation.
6. Remove the plastic hose from your return fitting at the pool, and
reattach to the large side (inlet) of your AquaPower-Plus. Fasten
with a stainless steel clamp.
7. Using the supplied plastic tube, fasten the tube to discharge end
of cell. Then fasten the other end to your pool return fitting that
you disconnected in step 6.
8. Open the valves you have closed our remove the plug installed
and check for any leaks. If leaking tighten down your fittings.
9. Add necessary salt per instruction manual directly to the
pool water.
10. Refer to wiring instructions to complete your installation.
22
UP/DOWN BUTTONS:
These are used to adjust the percent of chlorine level
output either during a real time display or if the view
button has been used to display the programmed
percent of chlorine output. They are also used to alter
the time periods displayed by the View button.
(The initial push of an UP/DOWN button will initiate the
set mode and the display will begin to flash. Further
pushes will alter the display).
POWER PACK CONTROL PANEL
OPERATIONAL UNDERSTANDING
On start-up, power is ramped up to the cell after a 10 second delay. At the end
of a time period, the cell will cease production 30 seconds before the pump
switches off. This delay allows the system to flush the pipe work and prevent
heavily chlorinated water diffusing through and damaging heater tube bundles.
When 100% chlorine output is set, full power is delivered to the cell, however
not for the entire ON time period. The cell power cycles on and off to achieve the
percentage chlorine output required. The power modulation can be witnessed by
observing the gas production at the cell.
7