AquaScape 91016 Інструкція та обслуговування - Сторінка 7

Переглянути онлайн або завантажити pdf Інструкція та обслуговування для Водяний насос AquaScape 91016. AquaScape 91016 16 сторінок. Pond pump

AquaScape 91016 Інструкція та обслуговування
– A centering bushing is required on both ends of the
impeller shaft, one bushing is located inside the pump
and an outer bushing sits in the water chamber cover.
– Slide the first interior bearing washer onto the ceramic
shaft (Ex. 20.
– Place the ceramic impeller shaft into the pump,
checking to be sure the centering bushing sits inside the
pump (Ex. 21).
Ex. 20

Winter Application

The pump can be run during freezing weather if desired, but should be removed if shutting down the pump for the winter.
Disconnect the tubing if using the side discharge fitting and remove the pump and fountain head from the pond. Clean the
pump and cage screens with fresh water and store the pump in a frost-free location.
aquascapeinc.com |
CAN (866) 766-3426 |
– Carefully, slide the impeller back onto the shaft. Use
caution, the impeller assembly is magnetic and will be
forcefully pulled back into the pump (Ex. 22).
– Install second outer bearing washer over the impeller
shaft (Ex. 23).
Ex.19
– The water chamber cover is replaced by lowering the
cover over the impeller shaft so the impeller shaft sits in
the impeller bushing. The cover tabs should fit inside the
matching slots on the pump face (Ex. 24).
– When the water chamber cover is rotated clock-wise
less than a ¼ turn, the pump discharge fitting on the
pump cover is in the vertical position (Ex. 25).
Ex.21
US (866) 877-6637
Ex. 22
Line Up Tab
Ex. 24
Ex.23
Ex.25
7