Diamond H2O Reliant DRS4-EM-66 Посібник - Сторінка 17
Переглянути онлайн або завантажити pdf Посібник для Диспенсер для води Diamond H2O Reliant DRS4-EM-66. Diamond H2O Reliant DRS4-EM-66 19 сторінок. Reliant drs4 series single tank water softener
- 1. Table of Contents
- 2. Place the Tanks Near a Water Source
- 3. Setting up the Tank
- 4. Connect the Brine Tank
- 5. Connect the Valves to the Water Source
- 6. Electrical
- 7. Start up the System for the First Time
- 8. Bypass Valve Operations
- 9. Main Operating States
- 10. Program the Valve
- 11. Troubleshooting
- 12. System Specifications
- 13. Error Codes
12. Troubleshooting
A. Manual Backwashing
Delayed Manual Backwash
A delayed manual regeneration is programmed by pressing the REGENERATION key. The
regeneration icon on the LCD will flash indicating regeneration will start when the time of day
reaches the programmed time of regeneration. Pressing the REGENERATION key again will
turn off the regeneration icon and cancel the delayed regeneration.
Immediate Manual Backwash
An immediate manual regeneration is programmed by pressing and holding the
REGENERATION key for three seconds. The regeneration icon on the LCD will turn on. The
control will go to the regenerating mode.
Delayed Second Backwash
A delayed second regeneration is programmed by pressing the REGENERATION key while the
control is in the regenerating mode. The x2 icon next to the regeneration icon will flash
indicating a second regeneration will start when the time of day reaches the programmed
time of regeneration.
Double Immediate Manual Backwash
Back to Back manual regenerations are programmed by pressing and holding the
REGENERATION key for three seconds while the control is in the regenerating mode. The x2
icon next to the regeneration icon will turn on indicating a second manual regeneration will
start immediately after current regeneration is complete.
B. Power Loss
Only the current time of day will need to be reset if power is lost for greater than 8 hours. If
power is lost while the system is regenerating, the control will complete regeneration at the
point of interruption once power is restored.
13.
CAPACITY & SALT per
REGENERATION
MODEL
MAXIMUM
Capacity
Salt/Regen
15,300
7.0 lb
DRS4-EM-15
24,600
10.5 lb
DRS4-EM-24
14.0 lb
32,800
DRS4-EM-32
32,800
14.0 lb
DRS4-EM-33
21.0 lb
49,100
DRS4-EM-49
28.0 lb
65,500
DRS4-EM-66
System Specifications
Table 6: System Specifications
SERVICE FLOW
MINIMUM
RATE (GPM) @ PSI DROP
Capacity
Salt/Regen
9,600
2.5 lb
3.8 lb
15,500
5.0 lb
20,700
5.0 lb
20,700
7.5 lb
31,000
10.0 lb
41,400
SOFTENER
TANK(S)
DIMEN's CAPACITY DIMEN's CAPACITY
Dia x Ht (in)
4.0 @ 5
7 x 35
6.0 @ 9
8 x 44
10.0 @ 15
9 x 48
5.7 @ 6
10 x 54
9.6 @ 15
12 x 52
11.2 @ 15
13 x 54
BRINE TANK
(With Grid)
Cu Ft
Dia x Ht (in)
Lbs.
0.5
18 x 33
300
0.75
18 x 33
300
1
18 x 33
300
1.5
18 x 33
300
2
18 x 40
400
2.5
18 x 40
400
PLUMBING
SERVICE
DRAIN
BW flow
Inches
Inches
(gpm)
¾, 1, 1 ¼
1.2
½
¾, 1, 1 ¼
½
1.6
¾, 1, 1 ¼
½
2.0
¾, 1, 1 ¼
½
2.5
¾, 1, 1 ¼
½
2.5
¾, 1, 1 ¼
½
3.5