Accurate Technology ProScale Посібник користувача - Сторінка 11
Переглянути онлайн або завантажити pdf Посібник користувача для Вимірювальні прилади Accurate Technology ProScale. Accurate Technology ProScale 20 сторінок. Flush mount readouts
Також для Accurate Technology ProScale: Посібник із швидкого старту (17 сторінок)
Output mode 3
Position<delimiter>Units<delimiter>ID<terminator>
Example:
inches with <space> delimiter, unit ID 3:
millimeters with <space> delimiter, unit ID 2:
Output mode 4
Full Message Display
The full message display mode provides two types of messages depending on
the type of signal received.
•
Position Information
•
Status Information
When position information is received, the resulting message output is:
Position<delimiter>Units<delimiter>ID<delimiter>Signal Strength<terminator>
When status information is received, the resulting message output is:
Drift status<delimiter>Battery status<delimiter>ID<delimiter>Signal
Strength<terminator>
The position information is similar to Output Mode 3 with the addition of a signal
strength indication. Signal strength is represented by a value from 0 to 7 where
0 is a very weak signal and 7 is a very strong signal. This can be used for
verifying the quality of signal reception from a particular transmitter location.
The status information is used in conjunction with the drift monitor feature of the
ProScale General Purpose display. If the drift monitor is enabled on the display
and movement is detected outside the drift tolerance range, the display will
indicate a drift condition and a drift signal will be sent on the RF channel. If a
low battery condition is detected, this will also be indicated in the status
information.
In the case of the Full Message Display option, the "delete previous
measurement" message (see: Deleting a previous measurement record) is in
the format:
DEL<delimiter>ENTRY<delimiter>ID<delimiter>Signal Strength<terminator>,
where DEL is substituted for the position and ENTRY is substituted for the
units.
Example (position information):
inches with <space> delimiter, unit ID 3, signal strength 5:
millimeters with <space> delimiter, unit ID 2, signal strength 7:
Accurate Technology Inc.
5.637 IN 3
28.35 MM 2
5.637 IN 3 5
28.35 MM 2 7
Page 11 of 20