Accurate Technology ProScale Посібник користувача - Сторінка 12
Переглянути онлайн або завантажити pdf Посібник користувача для Вимірювальні прилади Accurate Technology ProScale. Accurate Technology ProScale 20 сторінок. Flush mount readouts
Також для Accurate Technology ProScale: Посібник із швидкого старту (17 сторінок)
Output mode 5
Binary mode output, ProRF emulation
This output mode is intended to be used with applications that were designed
for the ProRF two-way radio interface system. The output from this receiver is
a small subset of the functionality from the ProRF. Since the ProScale RF
receiver is one-way only, no acknowledgment signal can be sent back to the
display.
The binary message packet reports a combination position/status message
This message packet is described below in an outline format. For detailed
information regarding the ProRF communication format, review the document
entitled: "ProRF System Definition and Communications Protocol Architecture"
available from Accurate Technology, Inc.
Measurement Sample:
Receiver's
Address
[255] (Base)
Byte 1
Module
Module
Type
Status
[1]
[0 – 0xFF]
Byte 7
Byte 8
Note: In the ProScale RF emulation mode, bytes 7 through 10 of the message
are fixed at 1, 0, 1, and 1 respectively.
ProScale RF Receiver User Manual
Sender's
Command
Address
Header
[1 –254]
Byte 2
Byte 3
Encoder
Status
[0 – 0xFF]
Byte 9
RSSI
Value
['A']
['1' – '7']
1 = low
signal
7 = high
signal
Byte 4
Data Capture
Latch
[0 – 0xFF]
Byte 10
Message
Number of
Packet
Data Bytes
ID
[0 – 255]
Byte 5
Units of
Operation
Position Data
[0] = mm.
['0' – '9' '.' '-']
[1] = in.
Byte 11
Bytes 12 - 19
Page 12 of 20
[13]
Byte 6
ASCII