RF160 - 2CH SMART RF Output Module - 433MHz
The 2 Channel SMART RF Wireless Output Module, is
an advanced 433MHz RF transceiver with 2 indepen-
dently controllable relay outputs. Output functionality is
configured via panel programming, and any number of
RF outputs can be used, up to the maximum number of
outputs supported on the panel.
The panel must be fitted with one or more RF120 and/or
RF121 Smart RF Receivers (V2.51or higher).
The unit is compact so it can easily fit inside a gate
controller cabinet or can be mounted easily to most
surfaces. The wide operating voltage 9 to 28 volts AC/DC
makes it easy to power from third-party controllers or
power supplies.
The 2-Way communication protocol is encrypted with
rolling code and anti substitution technology making
the RF160 an ideal choice for controlling gates, garage
doors, lights or security systems.
Box Contents
The RF160 box contains the following parts.
2 Channel SMART RF Stand Alone Controller
1 x Antenna Instruction Sheet
Compatible Keyfobs
RF110 Smart 5 Button Keyfob
RF110FK - Colour Facia Kit One Of Each Colour
(Red, Blue, Green, Orange, Black, Grey, Yellow)
Figure 1: RF110 Smart 5 Button Keyfob
Mounting Considerations:
•
The receiver should be mounted in a location at
least 2 metres from other receivers.
Page
2
P/N: RF160IRG Rev 1.0
•
The receiver should be mounted on a vertical sur-
face with at least 30cm clearance from metal objects.
•
Avoid mounting the receiver in areas with significant
metal or electrical wiring.
•
Avoid mounting the receiver in areas where it may
be exposed to moisture or high humidity.
•
Reception distances are generally improved with
higher mounting locations and with no metal ob-
jects near the unit.
•
If range is not achievable due to environmental or
specification limitations then look at relocating the
unit to a more appropriate location.
Receiver Operation
The RF160 will turn on the green RX LED to indicate the
unit is powered and it will blink off each time a signal is
received. Each time a Keyfob button is pressed the corre-
sponding relay will operate and a confirmation signal is
sent to the Keyfob to indicate a successful 2 way transac-
tion. When button RLY1 or RLY2 are triggered manually
they operate the corresponding relay to allow you to
test your connections and device your operating.
WARNING always be sure to check that there is no ob-
jects in the way when operating an automatic device as
this could cause damage or injury to a person.
Relay Programming
Before configuring RF outputs, the control panel needs
to be communicating to an existing Digiflex smart RF
receiver (refer to both the control panel and smart RF
receiver installation manuals for further information).
You need to configure an output at the control panel
from the available event types provided - refer to the
control panel installation manual for further information.
Each relay on the RF160 can follow a single control panel
output when the event occurs.
Configuring Output At Control Panel - Example
The example below will configure an output to operate a
garage door controller (in this example using output 6).
MENU 4-1-0 Output Name < Garage Door >
MENU 4-1-1 Event Type < 60 = Door >
MENU 4-1-2 Event Assignment < 01 = Door 1 Name >
MENU 4-1-3 Output Polarity < 04 = Open, 1 Shot Low >
MENU 4-1-4 Output Time Parameter < 001 Second >
E&OE