digigate slider ROBO 24 Посібник - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник для Відкривач воріт digigate slider ROBO 24. digigate slider ROBO 24 7 сторінок. Sliding gate operator
Height adjustment
For the height adjustment to be possible, the four adjusting screws
provided in the small accessory box must be fitted as in fig. 9 on page 7, before
mounting the machine to the steel base plate. Ideally, these screws should protrude 5 to
10 mm, creating a gap between the base plate and the under side of the machine. This
will allow for subsequent height adjustment.
Wiring For all connections refer to Fig. 1.
Mains.
A suitable cable (armoured 3-core or Surfex) should be used from a 2-
circuit breaker on the distribution board to the site of the motor, where it is
brought up through the opening in the base plate. See page 5 Fig. 4. Connect
the earth wire and the armour to the spare lug provided on the chassis earthing
point. Connect the Line and Neutral wires to the terminals 'L' and 'N' on the
controller, shown as '230V MAINS' in Fig. 1.
L N N L
+ - + -
LAMP
BATTERY MOTOR
MAINS
230V~
Accessories.
Before connecting any accessories, decide which 'Type' of operating mode will be
used, 'Standard' or 'Commercial'. 'Standard' is suitable for residential purposes, giving
each user full control of the gate. 'Commercial' avoids conflicting inputs by providing a
dedicated 'Open' input for the users. Separate 'Stop' and 'Close' connections are also
provided.
Note: All the accessories are referenced to '0V-COM'.
N.C. and N.O. refer to switch contacts, and stand for 'Normally Closed' and
'Normally Open'.
Partial. For pedestrian use, a key Switch may be connected to 'Partial'.
This switch will cause the gate to open to a width of about 1,2m. Once partially opened,
the gate may be re-closed using the same switch, or it will auto-close in the time
selected (5, 10 or 20 seconds) or in 5 seconds if Auto-close is not selected.
If the gate is closing after being partially opened and the safety beam is blocked, the
gate will only re-open to the partially open point.
PROGRAM DISPLAY
PLUGGABLE MEMORY
ENTER BUTTON
SELECT BUTTON
STANDARD
PARTIAL
CONTROL
LOCK
ON/
LIGHT
OFF
0V-COM
BEAM N.C.
BEAM 24V+ BEAM 24V+
GATE
STATUS LED+
ANTENNA
0V-COM
MANUAL
ENCODER
Fig. 1
24V DC
2
TYPE
COMMERCIAL
PARTIAL
OPEN
STOP
CLOSE
0V-COM
BEAM N.C.
GATE
STATUS LED+
amp