Display Programming
For correct functioning is necessary to programme correctly the inner parameters of the instrument:
Press RESET for 2 seconds to switch on the instrument, now press at the same time all the 3 keys for
about 6 seconds until on the display appears the value of the first constant, now leave again in order as
first key TIME then key METER and as last key ENTER.
On display appears the first constant with the first digit blinking, to change the value use key METER to
increase the blinking digit and key TIME to move the blinking digit. Once put in the value required press
RESET to confirm it and pass to the following constant: it appears C2 (constant 2) for about 1 second
and then follows the relative value.
To see all the constants without change them you can press on METER and run them in order.
To step out of the programming press on key TIME.
To modify the selected constant press RESET and the first digit will start to blink ready to be modified
with keys METER and TIME; press again RESET once put in the value required.
+
+
TIME
METER
RESET
RESET
METER
TIME
The constants to be programmed are:
C1
Tube diameter in millimetre
Range allowed from 1 to 999 mm.
C2
Coil diameter in millimetre
Coil diameter on which is wound the tube, range allowed from 1 to 9999mm.
This constant has 4 digits and given that the display has only 3 digits, have to be programmed
first the 3 less important digits then press on key TIME until appears H00 and programme the last
digit. With TIME its possible to go back on the 3 digits and with RESET to confirm the value.
C3
Coil layers number
Number of coils one of top of the other; range allowed from 2 to 99
C4
Number of coils placed side by side for each layer
Number of coils placed side by side for each layer; range allowed from 2 to 99
C5
Number of coils on the last layer
Number of coils wound on the most external layer; range allowed from 2 to 99
C6
Impulse number for each turn of the coil
Number of turns of the shaft on which is mounted the transducer to have 1 turn of the coil on
which is wound the tube; range allowed from 1 to 9999. Also this constant has 4 digits and it
worth as written for constant C2
C7
Tube length in meter
Total length of tube wound on coil; range allowed from 1 to 999
C8
Reducing of tube diameter for crushing
This constant with the following one is for compensation of crushing on the first coils. Its
expressed in per cent of tube diameter, for example, defining a value of 98, the diameter will be
reduced of 2%. Range allowed from 50 to 99.
C9
Number of layers on which reduce the tube diameter
Its the number of layers on which we consider the reducing of diameter caused by crushing.
Data: 20/02/06
Pressed together for 6 second to enter in programming
To modify and confirm the constant in order to be changed
To run all the constant and increase the blinking digit
To go out of the programming and to move the blinking digit
File : VIR_SP_ing.doc
(default value 50)
(default value 500)
(default value 5)
(default value 5)
(default value 5)
(default value 500)
(default value 99)
(default value 99)
(default value 2)
Rev:1.2