Connection scheme

PUSH-PULL OUTPUT

(type: MTP1)
Brown
+10÷25 VDC
Yellow
signal A
White
signal B
Gray
signal Z
Geen
GND
Shield
internally not connecetd
Output signals
The measure transducer turns the shifting compared to the magnetic band in digital signals with two squaring
channels (A, B) very similar to the signals produced by incremental encoders or optical lines. Every 5 mm you
have a reference impulse (Z) which can be used as the zero-setting signal of the quota. Pay attention: if the
reference signal Z isn't used it has to be isolate electrically of the other signals and of the power supply.
signal A
signal B
signal Z
Data: 13/01/16
0,04 mm
0,02 mm periodic every 5 mm
LINE DRIVER TTL OUTPUT
(type: MTP2, MTP3, MTP4)
Brown
Yellow
Orange
White
Purple
Gray
Black
Geen
Shield
RESOLUTION
0,04mm x1 count
0,02mm x2 count
0,01mm x4 count
file: MTP_ing.doc
+10÷25VDC / 5VDC
signal A
signal /A
signal B
signal /B
signal Z
signal /Z
GND
internally not connecetd
:
MTP_
pag 5/5