Bitspower Hercules Pump V3 Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Водяний насос Bitspower Hercules Pump V3. Bitspower Hercules Pump V3 15 сторінок.
Protection
Idle protection
When there is no liquid in the pump, the water pump will enter an idle speed protection mode
and run at full speed within 5 seconds.
After 5 seconds of idling, the water pump will temporarily stop running.
The pump will restart automatically after 5 seconds.
After repeating this cycle 10 times, the pump will completely stop running and will not start
again.
At this time, the power needs to be turned off before restarting.
If normal water flows through the pump before the pump stops running completely, the pump
will keep running normally.
Over / Under Voltage Protection
Over Voltage Protection 20±1V
When the input voltage is higher than the protection value, the pump will stop running within 2
seconds.
When the input voltage is lower than the protection value, the water pump will resume running
within 2 seconds.
Under Voltage Protection 6±1V
When the input voltage is lower than the protection value, the pump will stop running within 2
seconds.
When the input voltage is higher than the protection value, the water pump will resume running
within 2 seconds.
Rotor lock protection
When the rotor of the pump is blocked, the pump will automatically stop running, and resume
running after 5 seconds.
If the pump rotor continues to clog, the restart time will be extended to 15 seconds after 5
restarts.
Reverse voltage protection
When the positive and negative poles of the water pump are accidentally reversed
with 20V of power, the water pump will not run thereby preventing irreparable damage.
[ 4 ]