Cisco TelePresence IX5200 Перше налаштування - Сторінка 39
Переглянути онлайн або завантажити pdf Перше налаштування для Конференц-система Cisco TelePresence IX5200. Cisco TelePresence IX5200 40 сторінок.
Також для Cisco TelePresence IX5200: Посібник користувача "Швидкий старт (15 сторінок), Посібник користувача (26 сторінок), Посібник з монтажу (36 сторінок)
Retrieving and Reading the Results of the Noise Level and
Reverberation Tests
After you run the noise level and reverberation tests, you can retrieve the reports by navigating to
Logs > Reports in the Administration GUI. You see a list of .html files whose filenames begin with
Noise and RT60. Click Download to open and view the reports in an HTML browser.
Figure 7
Reports Screen and RT60 and Noise Level HTML File Example.
Most of the information in the HTML files is self-explanatory. More descriptions of the fields follow:
•
•
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of
Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The
use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)
©
2014-2017 Cisco Systems, Inc. All rights reserved.
OL-27038-01
MicBar column (for RT60 and Ambient Noise results): The numbers in MicBar area 1, 2, and 3 refer
to the left, center, and right microphone bars, respectively. If you have a two-row system, 4 to 9 refer
to the second row mic bars, going from left to right.
0.0 result (RT60 reverberation test only): If the RT60 measurement is 0.0, the result was out of
range. This condition can be caused by a high level of noise in the room. Repeating the test should
cause a valid result above 0.0 to appear. If, after rerunning the tests, the results are still 0.0,
reverberation in the room is very high, which will adversely affect the audio quality of TelePresence
calls. Remediation procedures, such as adding an acoustic panel in the room to reduce reverberation
and room noise, might be required.
Retrieving and Reading the Results of the Noise Level and Reverberation Tests
Cisco TelePresence IX5000 and IX5200 First-Time Setup
39