Binning
By adding 2 vertical pixels or 2 horizontal pixels, the
frame rate is increased the sensitivity. The color camera
cannot set this. This can be set with or without a trigger.
Partial scan can be used concurrently and horizontal and
vertical can be set at the same time.
Command
Parameter
VBIN
1
2
HBIN
1
2
Output Bit Length
Toggling between 8 bit/10 bit/12 bit for monochrome
camera, and toggling between Raw output 8 bit/10 bit/
12 bit and RGB output 24 bit for color camera are
available.
Command
Parameter
PIXEL-DEPTH
8/10/12/24*
* XCL-CG510C only
Image flip
Flips an image vertically and horizontally.
Reboot the unit to reflect the changes of the setting.
Register
Parameter
REVERSEX
REVERSEY
Setting
No binning
Vertical binning
No binning
Horizontal binning
Function
0/1
0: Normal
1: Inversion
0/1
0: Normal
1: Inversion
Gain
Manual gain
Manual gain can be set finely in 0.1dB increments.
Although the settable lower/upper limit values of the
gain are slightly different in each camera, the GAIN
parameter value can be set from –1 dB or less to 27 dB
or more. Same as the gain, the parameter value of the
GAIN-FINE can be set from –10 or less to 270 or more.
The setting range of the gain that guarantees image
quality is from 0 dB to 18 dB.
Command
Command parameter
GAIN
–1 or less ~ 0 ~ 27 or more
GAIN-FINE
–10 or less ~ 0 ~ 270 or
more
Auto gain (AGC)
By executing the GAIN-AUTO command, the gain is
automatically adjusted according to the image pickup
environment. AGC works so that the average level in a
detection frame may reach AGC-LEVEL. The AGC
detection frame is set to the central region by default.
The detection frame can be displayed or the detection
area changed.
Command
Parameter
GAIN-AUTO
(AGC)
AGC-LEVEL
0 to 11264 to
16383
AGC-SPEED
1 to 256
AGC-UPPER
0 to 18
AGC-
0 to 18
LOWER
AGC-
FRAME-
HIGHLIGHT
Command Parameter
1
AGC-
1 to 100
FRAME
18
Setting
Gain dB unit
Gain advanced
setting
Setting
0
Manual gain
1
One-push AGC
2
Continuous AGC
AGC target level (14 bit)
AGC convergence speed
AGC upper limit (dB)
AGC lower limit (dB)
0
AGC detection frame is
hidden
1
AGC detection frame is
displayed
Parameter
Parameter
Parameter
2
3
1 to 100
0 to 99
0 to 99
4