3.1.4 CR Motor Removal
1. Remove "Housing, Upper". (Refer to Service Manual of GT-9500)
2. Remove Bottom plate. (See "Bottom Plate Removal" on page -14)
3. Remove B077 Main Board. (See "B077 MAIN Board Removal" on
page -15)
4. Remove 5 screws(CBS, M3x6) securing "Center Rail" and "Shield
Board" from the back of scanner. Also, remove one screw(CB, 3x6)
securing "CR Motor Assembly", earth plate, and motor from the
back of scanner.
CB(3x6)
CBS(M3x6)
Figure 3-5. Screws at the Circuit Board Side Removal
Disassembly and Assembly
5. Remove carriage assembly. (Refer to Service Manual of GT-9500)
6. Remove 3 screws(CBB, 3x12) securing "Center Rail" to "Housing,
Lower", and one screw (CBS, M3x6) securing "Center Rail" to "CR
Motor Frame".
7. Remove 2 screws(CBS, M3x6) securing "Earth Plate, Front" and
"Frame, Front", and remove "Center Rail".
Housing, Lower
Center Rail
Disassembly and Assembly
CBS(M3x6)
CBB(3x12)
Figure 3-6. Center Rail Removal
Revision A
Earth
Plate,
Front
Frame,
Front