12. AUTO P/L pulses per litre, automatic
Select Day counter or Total counter and keep the Mode
button pressed for 5 seconds.
If the unit is protected by a code, you will be requested
to enter this code (Code, Chapter 14).
SYSTEM LED is illuminated.
ALARm is shown on the display.
In Setting mode, if no button is pressed for 30 seconds,
the display goes back to the Day counter.
Press the Up button twice to switch to AUTO P/L setting
(pulses per litre, automatic).
AUTO P/L is shown on the display. Now press the Mode
button once again to automatically start calibration. On
the display, a line appears that moves from right to left
during data acquisition.
Now allow approximately 1.0 litre of medium to flow
through. Afterwards press the Mode button once.
Set the measured quantity (set of scales/graduated bea-
ker) in litres here. Use the Down/Up buttons to change
the value and the Mode button to switch to the next digit.
For example, a value of 1.038 Liter:
Press Up button 8x, Mode button 1x, Up button 3x, Mode
button 2x, Up button 1x and Mode button 2x.
AUTO P/L is shown on the display.
Press the Up button once briefly to switch to COdE setting.
Or press the Mode button for 5 seconds to go back to
the Day counter.