Whirlpool 8527813 Інструкція з монтажу Посібник з монтажу - Сторінка 3

Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сушарка Whirlpool 8527813. Whirlpool 8527813 13 сторінок. Commercial stacked dryer gas & electric

The collar houses the accumulator
timers with actuating arm and button.
The timers are set to provide 45
minutes (4 pins) of drying time when
activated by the coin slide. Timer
cams for 30-minute (6 pins) and 60-
minute (3 pins) drying times are
included in the parts bag.
The coin-slide mechanism, control
panel lock and key, and coin-box lock
and key are not included and are
available from usual industry sources.
To change to a
30- or 60-minute
timingcam
WARNING
Electrical Shock Hazard
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.
Each coin-operated dryer is
equipped with a 45-minute timer
cam that provides 45 minutes of
drying time when activated by the
coin slide.
You can install the 30-minute or
60-minute timing cam (shipped with
dryer) as follows:
1. Unlock control panel. Lift up and
rotate out from cabinet. Control
panel will still be attached to
cabinet.
2. Reach into control panel area.
Use Phillips screwdriver to loosen
(but not remove) timer mounting
bracket screw. Lift up to remove
timer assembly and bracket from
cabinet.
ratchet tooth
timing cam
3. Turn the timing cam by hand until
the "V"-shaped notch lines up
below the ratchet tooth.
timing cam
ratchet tooth
Line up
notch to
clear
hub
ratchet
down
tooth.
4. Insert a narrow, flat-blade
screwdriver under the timing cam
near the clock shaft. Gently lift cam
straight up and off shaft making
sure that the "V" -shaped notch
clears the ratchet tooth.
5. Place new cam (hub side down)
over clock shaft. Line up flat side of
shaft with flat side of cam hole.
Check that drive lug is in place.
6. Turn cam until "V" -shaped notch
lines up with ratchet tooth.
7. Press cam down in place on motor
shaft. Make sure that "V" -shaped
notch clears the ratchet tooth.
8. Reattach the timer bracket
assembly; then tighten the screws.
9. Repeat steps for other timer.
10. Close and lock the control panel..
Exhaust
requirements
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to do so can result in
death or fire.
Do not use non-metal flexible vent,
metal vent that is smaller than four
inches in diameter or exhaust hoods
with magnetic latches.
The dryer must be exhausted outdoors.
Do not exhaust dryer into a gas vent,
chimney, wall, ceiling, or concealed
space of a building.
Do not install flexible vent in enclosed
walls, ceilings or floors.
If using an existing exhaust system,
clean lint from entire length of exhaust
system. Make sure exhaust hood is not
plugged with lint.
The exhaust system should be
inspected and cleaned yearly.
Replace any plastic or metal foil
exhaust vent with rigid metal or
flexible metal vent.
drive
lug
Use 4" (10.2 cm) vent clamps to
secure vent system.
better
exhaust
airflow
Four-inch (10.2 cm) metal exhaust vent
is required. Plan installation to use the
fewest number of elbows and turns.
Metal flexible vent must be fully
extended and supported when the
dryer is in its final position. DO NOT
KINK OR CRUSH THE VENT. The metal
flexible vent must be completely
open to allow adequate exhaust air
to flow.
Allow as much room as possible
when using elbows or making turns.
Bend vent gradually to avoid kinking.
Remove excess flexible vent to avoid
sagging and kinking that may result in
reduced air flow.
Exhaust outlet is located at the
center of the bottom dryer back.
The exhaust vent can be routed up,
down, left, right, behind the dryer or
straight out the back of the dryer.
Maximum length of exhaust system
depends upon the type of vent used,
number of elbows and type of
exhaust hood. The maximum length
for both rigid and flexible vent is
shown in the chart.
4"
(10.2 cm)
No.
of 90°
turns
(10.2 cm)
MAXIMUM LENGTH OF 4-INCH (10.2 cm) DIAMETER
0
1
2
3
4
MAXIMUM LENGTH OF 4-INCH (10.2 cm) DIAMETER
0
1
2
3
4
exhaust airflow
good
exhaust
airflow
EXHAUST HOOD TYPE
4"
OR
(10.2 cm)
(10.2 cm)
4"
4"
2-1/2"
(10.2 cm)
(6.4 cm)
RIGID METAL VENT
64 FT. (19.5 m)
58 FT. (17.7 m)
54 FT. (16.5 m)
48 FT. (14.6 m)
38 FT. (11.6 m)
44 FT. (13.4 m)
29 FT. (8.8 m)
35 FT. (10.7 m)
21 FT. (6.4 m)
27 FT. (8.2 m)
FLEXIBLE METAL VENT
28 FT. (8.5 m)
36 FT. (11.0 m)
31 FT. (9.4 m)
23 FT. (7.0 m)
19 FT. (5.8 m)
27 FT. (8.2 m)
17 FT. (5.2 m)
25 FT. (7.6 m)
15 FT. (4.6 m)
23 FT. (7.0 m)
Page 3
4"