Alemite 8424 Посібник з експлуатації - Сторінка 7
Переглянути онлайн або завантажити pdf Посібник з експлуатації для Вимірювальні прилади Alemite 8424. Alemite 8424 9 сторінок. Flow meter
Flow Meter
9. NO OPERATION - The 8424 stores the
new work calibration factor and is ready
to begin dispensing, using the USER K
FACTOR that has just been calculated.
Meters Configuration
8424 features a menu with which the user can select
the main measurement unit, Quarts (Qts), Pints (Pts),
Liters (Lit), Gallons (Gal); The combination of the unit of
measurement of the Partial register and that of the Totals is
predefined according to the following table:
Unit of Measure
Combination
of the Partial
Register
1
Liters (L)
2
Gallons (Gal)
3
Quarts (Qts)
4
Pints (Pts)
To choose between the 4 available combinations:
• Wait for 8424 to go to Standby,
• Press the CAL and RESET keys together. Keep these
pressed until the word "UNIT" appears on the screen
together with the unit of measurement set at that
time (in this example Liters/Liters
• Press the reset key to select the desired combination
of unit of measurement, amongst those shown below.
• Save the new combination by pressing the cal key at
length. 8424 will pass through the start cycle and
will then be ready to dispense in the set units.
WARNING
The Resettable Total and Total registers will be
automatically changed to the new unit of measure-
ment. NO new calibration is required after chang-
ing the Unit of Measurement.
Alemite, LLC
Maintenance
of maintenance. The only types of maintenance required
are the following:
1. Battery change – necessary when the batteries have
2. Cleaning of the turbine with washing or mechanically-
Battery Replacement
Register Unit of
Measure of the
SIZE AAA. 8424 features two low-battery alarm levels:
Totals Register
1. When the battery charge falls below the first level on
Liters (L)
Gallons (Gal)
Gallons (Gal)
operate correctly, but the fixed icon
warns the user that it is ADVISABLE to
Gallons (Gal)
change the batteries.
2. If 8424 operation continues without
Do not discard the old batteries in the environ-
ment. Refer to local disposal regulations.
diagram positions, proceed as follows:
Total and the same Partial indicated before the batteries
7
8424 has been designed to require a minimum amount
run down.
handling.
8424 is complete with 2 x 1.5 V. alkaline batteries
the LCD, the fixed battery symbol appears.
In this condition, 8424 continues to
changing the batteries, the second
battery alarm level will be reached
which will prevent operation. In this condition the
battery icon starts to flash and is the only one to
remain visible on the LCD.
WARNING
To change the batteries, with reference to the exploded
• Press RESET to update all the totals
• Loosen the 4 screws securing the lower cover
• Remove the old batteries
• Place the new batteries in the same position as the
old ones
• Close the cover while positioning the rubber guard
as a gasket
• 8424 will switch on automatically and normal
operation can be resumed.
The 8424 will display the same Reset Total, the same
SER 8424
Revision (1-11)