ALUZ ZIBI A1 Series Посібник - Сторінка 9

Переглянути онлайн або завантажити pdf Посібник для Освітлювальне обладнання ALUZ ZIBI A1 Series. ALUZ ZIBI A1 Series 11 сторінок. Surface zuco pivot bios illuminated
Також для ALUZ ZIBI A1 Series: Інструкція з монтажу Посібник з монтажу (12 сторінок), Посібник (11 сторінок), Посібник (13 сторінок), Інструкція з монтажу Посібник з монтажу (11 сторінок)

TROUBLESHOOTING TIPS

• Do not reset the breaker multiple times.
• If the unit is overloaded, the breaker will trip, shutting off the driver and lights.
• If the breaker reset button has been held down by hand or any type of pressure,
such as duct tape, or if the breaker has been reset multiple times without
troubleshooting, the unit will:
- Burn the driver bobbin.
- Burn the thermal or magnetic breaker.
- Burn the driver lead wires due to high amperage caused by overload.
- Short circuit in line which will not allow the breaker to reset.
- Damage the lighting.
1
Turn off power before beginning. Verify power is off by using a not contact
circuit tester (by others).
2
Check the board for damage, such as cuts, punctures, twisting, or crushing.
If there is excessive damage to the board, it must be replaced.
Damaged Board
3
Check the run for any particles that may cause a short. Check the end cap,
power connector, and board for any metal flakes or shavings. Clear the run of
any shavings or particles if present, then perform a continuity test to confi rm
the short has been eliminated.
Foreign Object
4
Check board cuts to ensure they are clean. Frayed, split, or sloppily cut boards
can damage the circuit, resulting in flickering, dimness, or LED outages.
5
Check terminal connections between LED boards. If a terminal is loose,
damaged, or absent, the board must be replaced. Check soldered
connections to LED boards, if applicable.
Broken Solder Connection
6
Check connections in the line. Ensure all splice connections are secure and
properly sealed with shrink tube and silicone for outdoor applications.
Ensure that wiring is not bent past the permitted wiring bend radius (1.5").
7
Check the run for any water inside end cap, power connector, or lightstrip.
If water or condensation is present, the lightstrip must be replaced.
1170 N Red Gum St, Anaheim, CA 92806
aluz.lighting
© ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
A1 Series | Surface
ZUCO Pivot BIOS Illuminated
(A1-ZUCO-PVT-BIOS)
Metal Flakes
Poor Quality Cut
Damaged LED
Damaged Connection
866.ALUZ.LTG | 714.535.7900
Page 9 of 11
Troubleshooting
Installation Instructions
8 / 9 / 2023 / Rev 0