(1)What type of system terminals are used in the heating circuit? 
Reply 
 
The unit is a cooling only model
 
Radiant panels (Floor, etc....)
Fan coils or low temperature radiators
 
Other applications
(2) Is the remote panel accessory installed (PR3) ? 
Reply 
 
Not installed
 
Installed
(3) Is the production of DHW envisioned? 
Reply 
 
Not envisioned
 
Envisioned
(4) Is a 3‐way diverter valve envisioned in the DHW production circuit? 
Reply 
 
Not envisioned
 
Envisioned
(5) Is a room thermostat installed? 
Reply 
 
Not installed
 
Installed
 
 
 
.
10  
 
Operations to be performed 
 
Go to question 2
Set the parameter StC (index 3 USER menu) with the value of 35 C
Set the parameter StC (index 3 USER menu) with the value of 45°C(default 
 
value)
 Set the parameter StC (index 3 USER menu) with the value of 55 °C
Operations to be performed 
 
Go to question 3
Set the parameter PAN (index 9 INSTALLER menu) with the appropriate value, 
 
selecting from:
 
Value (1):
 • Season control piloted from the circuit board
• ON/OFF control enabled from PR3
 
Value (2):
 • Season control enabled from PR3
• ON/OFF control from panel on machine
 
 Value (3):
 • Season control enabled from PR3
• ON/OFF control enabled from PR3
Operations to be performed 
 
Go to question 5
Set the parameter ASA (index A INSTALLER MENU) with the value (1)
Operations to be performed 
 
Go to question 5
Set the parameter AAS (index C INSTALLER menu) with the appropriate value 
(in seconds). This parameter indicates the stand‐by  tome for inversion
 
of the 3‐way diverter valve on the DHW 
Operations to be performed 
 
No operation
This parameter enables a digital clamp ID (indicated on the circuit board with 
the code TRA) to which a room thermostat must be connected, used to disable 
the compressors and the integrative resistances. Set the parameter trA (index 
D INSTALLER menu), with the appropriate value, selecting from:
 
Value (1 or 2): Clamp ENABLED
 
Value (0 or 3): Clamp DISABLED
Remember that the OPEN state on the clamp  represents:
• the compressors and resistances block function if the parameter is set at 1
• the compressors, pumps and resistances block function if the parameter is 
 
set at 2
• represents the pump alarm (as in the previous software version), if the pa‐
 
rameter is set at the value 3
 
 
 
 
 
 
 
 
 
 
 
production system