ASG EasyLine 4G Посібник з встановлення та експлуатації - Сторінка 12

Переглянути онлайн або завантажити pdf Посібник з встановлення та експлуатації для Блок управління ASG EasyLine 4G. ASG EasyLine 4G 16 сторінок. Miniature phone line (pstn) simulator

ASG EasyLine 4G Посібник з встановлення та експлуатації

INPUT settings

The module has 1 SMS input. The type of input can be changed. It can connect to the GND point in a normal
closed position, i.e. Normal Close (NC) or in a normal position, i.e. Normal Open (NO). By changing the loop
formed between the input and the GND point, an SMS notification or a phone call can be triggered to up to
8 phone numbers. You can change the text of the SMS and the phone number to be notified at any time using
1 SMS.
In the Input panel, you can choose how the input should work:
At the input, you can specify whether it should be open (NO – Normal Open) or closed (NC – Normal
Close) by default.
We can also request an SMS notification of the status of the input. The reset SMS text can be
entered on the other tab in the SMS text for input reset.
In the case of signaling with a siren sound, the voice call message will be a 25-second siren sound,
while if you also select the voice message, then only 5 seconds.
It is possible to set the call not to be answered. In this case, the module will not initiate a call again
in case of a successful call, regardless of whether the call was actually received or not.
In the SMS text field, you can enter the content of the message, which can be a maximum of 32
characters long.
After saving the input settings, restart the module for the settings to work correctly!

Output settings

In the Output window, you can make settings related to the outputs. The type of output can be monostable,
i.e. single-state (it switches for a preset time, then returns to its original state), or bistable, i.e. two-state
(it returns to its original state only in case of a new control).
In the case of monostable operation, the desired switching time can be specified in seconds or minutes.
The maximum length of this can be 65,535 seconds.
After saving the output settings, restart the module for the settings to work correctly!
Setting the output is possible by sending the following message:
1234OUT1= → Optional parameteres: ON, OFF, RUN or switching for a specified time ( specified in 5
characters) ex: 1234OUT1=00003 → Control of Output 1 for 3 seconds.

Power monitor settings

The GSM device is capable of monitoring its own power supply and sending notifications in the event of a
problem.
• On the Power Monitor tab, you can set the voltage value below which the module sends an alarm.
• The additional settings of the function are the same as the settings of the inputs.
You can change the sending of the vital sign message with the SMS command below:
1234LIFETEST=cccsstttttttt
ccc → sending cycle specified in days (e.g.: 007 days)
ss → what time to send the messages on a given day
tttttttt → Whicj one phone number to send the messages to (ex.: 00100000 → sends the messages to
3
phone number)
rd
EasyLine 4G
www.ascglobal.eu
12