Cytech Comfort DM02 Посібник - Сторінка 7

Переглянути онлайн або завантажити pdf Посібник для Обладнання для запису Cytech Comfort DM02. Cytech Comfort DM02 16 сторінок. Door station interface

Comfort DM02 Door Station Interface
J2 - Tone: Shunt for louder Beep tone volume. This affects
w
specific Door station beeps like the beeping tone caused by lack of
communications. Default Open (soft).
J5 – Shunt J5 if the DM02 is to be connected to Comfort's DP04.
w
This will enable the LED indicator on the DP04 to be turned on
when the MIC is active.
SW1 – Set of 3 shunts to set the ID (see "Door Station ID
w

Switch").

LED Indicators

D8 – Turns on when the microphone circuit is enabled; i.e. the
w
outdoor intercom is in talk mode.

Trimmers

VR1 – MIC: Used to tune the microphone gain level from the
w
outdoor door station to Comfort.
VR2 - VOICE: Used to tune the speaker gain level from Comfort to
w
the outdoor door station.
Switch
SW2 – Doorbell: Simulates a press of the doorbell for testing.
w

Door Station ID Switch

Comfort is able to support up to 3 door stations. SW1 is a set of 3
headers which is used to determine the ID, in accordance to the following
table:
ID
1
2
3
In the Comfigurator software, the number of door station must be set to
equal the maximum (ID) number of door station in the system. Do not
set door stations with the same IDs as this clash of IDs will result in
communication failure.
After changing the ID of the door station, remember to reset the DM02
by unplugging and plugging the 12V/COM terminal block.
After setting the IDs of the door stations in the system, the total number
of door stations must be set in the system.
To do this, set the number of door stations in Comfigurator to the correct
number. This can be found under "Configuration"->"Modules and
Settings"->"Number of Door Stations".
SW1-A
Short
Open
Short
SW1-B
Short
Short
Open
SW1-C
Short
Short
Short