Cytech Comfort DM02 Посібник - Сторінка 6

Переглянути онлайн або завантажити pdf Посібник для Обладнання для запису Cytech Comfort DM02. Cytech Comfort DM02 16 сторінок. Door station interface

Comfort DM02 Door Station Interface

Specifications

Dimensions: 108 x 88 mm
w
Maximum Number of Door Station: 3
w
Power Supply: 12V (supplied by Comfort)
w

Contents

The DM02 package consists of the following*:
Comfort DM02 Manual (this booklet)
w
4 way cable for RS485 communications
w
4 x 2 way removable terminal blocks
w
3 x 3 way removable terminal blocks
w
*Subject to change without prior notice

Differences from DM01

DM02 is an improved RoHS-compatible version of DM01. It is able to
interface with more external intercoms than the DM01. DM02 will also
work with the new DP04 version of the Door Station

Settings

Connections

JP5 - COM2/NO2/NC2: Terminals for Relay Contact for Open
w
Door Response
JP4 - COM1/NO1/NC1: Terminals for Relay Contact for Open Gate
w
Response
JP3 – BELL/GND/12V_OUT: Connector for Doorbell Input: 5 to 24
w
VAC or + 5 to 24 VDC voltage input initiates the doorbell. If
doorbell input is DC, shunt J1 header to position 1-2. If doorbell
input is voltage-free contact, shunt J1 to position 2-3.
JP7 – MIC IN/SPK OUT: Connection to Intercom Outdoor Station.
w
JP6 – MIC OUT/SPK IN: Connection to Comfort MIC/VOICE.
w
JP2 - KA/KB: RS485 to Comfort
w
JP1 - 12V_IN/COM: Voltage supply from Comfort.
w
JP8/JP8A- Alternative connection for KA/KB/12V/GND (JP2 and
w
JP1) for short distances up to 1 meter from Comfort.

Jumper Settings

J1: Shunt J1 to positions 1-2 if the doorbell input (to BELL
w
terminal) is a DC signal of 5V to 24 VDC. Leave J1 open if the
Doorbell input is an AC signal 5 V to 24 VAC. Shunt J1 to positions
2-3 if the doorbell input is a voltage free contact. Default shunt.
2