Aktakom APS-7306 Benutzerhandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Stromversorgung Aktakom APS-7306 herunter. Aktakom APS-7306 12 Seiten. Programmable dc power supply
Applying Voltage to the Load
1. Press the Off/On key [1] to apply the voltage to the load.
The OUT [2] and C.V. indicators [8] light. The power supply
works in constant voltage (CV) mode; the display now shows the
actual output voltage and current.
If the current exceeds the set current limit, the power supply
automatically goes into constant current (CC) mode. The C.V.
indicator goes out and the C.C. indicator [7] lights.
2. Press the Off/On key [1] to switch the output off.
PROTECTION
Using Overcurrent Protection
1. To protect against overcurrent, set up the maximum current and
then press the OCP button.
2. Press Off/On to apply the output to the load.
If the output current becomes higher than the set value, the
power supply cuts off the output and the OCP indicator flashes.
3. Disconnect the load. To recover, press the OCP key.
7