Electrolux RH30WC60GSB Handbuch für Gebrauch und Pflege - Seite 5

Blättern Sie online oder laden Sie pdf Handbuch für Gebrauch und Pflege für Lüftungshaube Electrolux RH30WC60GSB herunter. Electrolux RH30WC60GSB 44 Seiten. 30" and 36" free-standing range hood

Electrolux RH30WC60GSB Handbuch für Gebrauch und Pflege
Important safety Instructions - Electrical & Installation
requirements
READ AND SAVE THESE INSTRUCTIONS
Electrical & Installation requirements
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
Before installing the hood
1.
For the most effcient air flow exhaust, use a
straight run or as few elbows as possible.
It is the customer's responsibility:
To contact a quali!ed electrical installer.
To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 -- latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code, Part 1 and
C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it
is recommended that a quali!ed electrician determine
that the ground path is adequate.
Do not ground to a gas pipe.
Check with a quali!ed electrician if you are not sure
range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspector's
use.
The range hood must be connected with copper wire
only.
The range hood should be connected directly to the
fused disconnect (Or circuit breaker) box through
metal electrical conduit.
Wire sizes must conform to the requirements of the
National Electrical Code ANSI/NFPA 70 -- latest
edition*,or CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No. 0-M91 - latest
edition**and all local codes and ordinances.
.
3.
.
5.
.
Vent unit to outside of building and recirculating.
At least two people are necessary for installation.
The hood is fitted with Screws and Drywall
Anchors suitable for most surfaces, consult a
Qualified Installer, check if they perfectly fit with
your cabinet/wall.
Do not use flex ducting.
COLD WEATHER installations should have an
additional backdraft damper that is already
installed to minimize backward cold air flow and a
nonmetallic thermal break to minimize
conduction of outside temperatures as part
of the ductwork. The damper should be
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
onthecoldairsideofthethermalbreak,
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Thebreakshouldbeascloseaspossible
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
towheretheductingenterstheheatedportion
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
ofthehouse,
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Makeupair:Localbuildingcodesmayrequirethe
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
useofMake-UpAirSystemswhenusingUucted
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
VentilationSystemsgreaterthanspecifiedCFMof
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
airmovement,
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
ThespecifiedCFMvariesfromlocaletolocale.
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
ConsultyourHVACprofessionalforspecific
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
requirementsinyourarea,
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
A U.L- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park
Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland,
Ohio 44131-5575