Danco GoBidet 2003 Schnellstart-Handbuch - Seite 2
Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Werkzeuge Danco GoBidet 2003 herunter. Danco GoBidet 2003 6 Seiten.
INSTALLATION INSTRUCTIONS - IMPORTANT NOTES
T
1.
his unit can accommodate hot and/or cold water installations.
For cold water only, it can be installed as purchased. Hot water
installation kits (Part no. 2003HIK) are available by calling
1.888.GoBidet.
2.
Your GoBidet™ will attach to a one-piece (tank and bowl are
molded into one piece) or two-piece (tank and bowl are separate)
toilet and a regular (round) or elongated toilet. See "Parts break-
down" page for instructions on changing the bushing bracket mounting
location.
3.
Use Teflon tape (provided) in all connections.
A. DISCONNECTING YOUR TOILET'S WATER SUPPLY LINE
1. Turn off water supply to toilet. It is usually an angle-stop/cut-off
valve on wall beneath toilet.
2. Empty toilet completely by holding flush handle down.
3. Put a shallow basin beneath water shut-off valve (at wall) and
water line connection at tank to catch excess water.
4. Disconnect water line from cut-off valve at wall and tank.
5. Clean and dry fittings and threads of tank and cut-off valve.
B. INSTALLATION INSTRUCTIONS
1. Remove toilet seat and clean mounting area.¹ Save seat
mounting parts to re-use.
2. After applying Teflon tape to its threads, attach braided "T" hose
(Part no. 2003.3W) to GoBidet™ housing by screwing male fitting
of "T" hose into inlet marked with a "C" in back of GoBidet™.
Tighten.
3. Determine if your toilet is a one-piece or two-piece unit. If you
have a one-piece unit please follow instructions on changing
bushing bracket (2003.09) mounting location (see center fold
page).
4. Insert threaded bushing of support bracket (Part no 2003.09) into
toilet bowl screw opening used for mounting toilet seat. Use
opening on your left when facing the toilet tank. Secure to toilet by
installing rubber washer first, followed by plastic washer and
chrome nut onto bottom of threaded bushing. Finger tighten only.
5.
Before tightening bushing completely, move shower arm (Part no.
2003.01) to its maximum extension, moving the support bracket
(Part no. 2003.09) until shower head is in center of toilet. Upon
retraction, shower arm should rest beneath rim of toilet. Finish
tightening bracket in place. DO NOT OVER-TIGHTEN BUSHING
OR TOILET WILL CRACK.
2