Danfoss iSave 21 Service-Handbuch - Seite 5

Blättern Sie online oder laden Sie pdf Service-Handbuch für Water Pump Danfoss iSave 21 herunter. Danfoss iSave 21 18 Seiten. Energy recovery device disassembling and assembling

Danfoss iSave 21 Service-Handbuch
Service guide
Disassembling and assembling iSave 21
7.
If bearing in flange need to be changed
gently press the bearing out from the
back side with a tube or a drift.
Place the new bearing in the hole in the
flange.
9.
Gently remove the cylinder barrel.
11.
Gently remove the housing.
Note: Loose parts on the inside of the flange.
180R9219 | 521B1171 | DKCFN.PI.003.K4.02 | 03.2016
8.
Lubricate the new bearing with clean
filtered water. With use of a hand press
gently press the new bearing in place
until it is in line with the flange surface.
Do not use a hammer!
10.
Unscrew the bolts in the flange.
Pin
12.
Remove port plate and pin.