TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES ( 59– 76, & 89):
With a 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B,
"#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F.
A "0" ( not "#+10") in the first box will disable a report.
A "0" ( not "#+10") in the second box will result in automatic advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A "0" ( not "#+10") in the second box will eliminate the expanded message for that report.
A "0" ( not "#+10") in both boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than "0") in the first box, to enable zone to report (entries in the
second boxes will be ignored).
A "0" ( not "#+10") in the first box will disable the report.
Examples: For Code 3 (single digit), enter:
For Code 3 2 (two digits), enter:
For Code B 2 (Hexadecimal), enter:
SYSTEM STATUS REPORT CODES ( * 59– * 68)
Field
Function
59
EXIT ERROR REPORT CODE
60
TROUBLE REPORT CODE
61
BYPASS REPORT CODE
62
AC LOSS REPORT CODE
63
LOW BAT REPORT CODE
64
TEST REPORT CODE
65
OPEN REPORT CODE
66
ARM AWAY/STAY RPT CODE
67
RF XMTR LOW BAT REPORT CODE
68
CANCEL REPORT CODE
RESTORE REPORT CODES ( * 70– * 76)
70
ALARM RESTORE RPT CODE
71
TROUBLE RESTORE RPT CODE
72
BYPASS RESTORE RPT CODE
73
AC RESTORE RPT CODE
74
LOW BAT RESTORE RPT CODE
75
RF XMTR LO BAT RST RPT CODE
76
TEST RESTORE RPT CODE
OUTPUT AND SYSTEM SETUP ( * 80– * 92)
80 POWERLINE CARRIER DEVICES
81 ZONE LISTS FOR DEVICES
83 SEQUENTIAL MODE (Also entered from field 56): See procedure later in this manual.
84 ASSIGN ZONE VOICE DESCRIPTORS. See procedure later in this manual.
85 RECORD CUSTOM VOICE DESCRIPTORS. See procedure later in this manual.
3 | 0
3 | 2
#+11 | 2
Programmed Values
[1]
2nd digit is automatically sent as 2nd digit of the zone alarm report
code programmed in 56, if expanded or 4+2 reporting is selected.
|
[1,0]
|
[1,0]
|
[1,0]
|
[1,0]
|
[1,0]
†† [1]
††
AWAY
STAY
|
[1,0]
|
[1,0]
[1]
2nd digit is automatically sent as 2nd digit of the zone alarm report
code programmed in 56, if expanded or 4+2 reporting is selected.
|
[1,0]
|
[1,0]
|
[1,0]
|
[1,0]
|
[1,0]
|
[1,0]
Program *80 and *81 only if Powerline Carrier Devices or chime by
zone are to be used. See procedure later in this manual.
6 –
–
[
] = Table 1 Default Value
[1,1] (
†† 2nd digit is automatically sent as the user
number if expanded or 4+2 reporting is selected.)