I N S TA L L AT I O N O F M E C H A N I C A L D R I V E U N I T
The ATA ELITE SWING GATE OPENER is designed to operate most domestic swing gates. The gates
must be in good working condition and should operate by hand relatively freely. Wind loading may affect the
operation of the opener in high wind areas, correct obstruction and reversing settings should be chosen for
trouble free operations
INITIAL CHECKING
STEP 1
Before commencing installation of the Elite Swing Gate
Opener, check the following:
1.The gate will move freely by hand for it's full opening and
closing travel.
2.The pier or post for mounting must be of solid construction
(Brick, solid timber or steel). It must anchor most of the
force applied by the drive unit.
3.A weatherproof 240V 10A general purpose Power Point
should be available on or near the pier/post.
FIG. 2
0
90
470
470
120
450
470
140
470
465
200
470
465
.
HINGE DISTANCE
50
100
125
150
SIDE ROOM CLEARANCE
470
470
470
480
470
465
470
465
460
445
430
400
4.If dual gate operators are required, provision for underground
cabling should be made from one post to the other.
5.Side Room Clearance. Using table 1 and referring to Fig. 2
check that there is enough room available to mount the Drive
Unit. If there is not, the Minimum Side Room Kit (Page 8) will
need to be purchased by your distributor from ATA.
6.The mount distance of the Drive Unit should be recorded. This
value will be used later.
TABLE 1
180
200
220
470
465
460
460
435
425
440
420
390
350
390
250
Page. 5
The mount Distance of the Drive Unit and the
Hinge Distance of the gates can be selected to opti-
mise the side room clearance.
NOTE: If the gates are already installed then
measure the Hinge Distance and use this to optimise
the Mount Distance.