ASSEMBLY INSTRUCTIONS
Clamp Head Installation
The post of the string clamp head and the tube of the
string clamp base are treated with grease to provide
protection against corrosion during shipping. Remove
any excessive grease with a clean cloth prior to use. The
post and tube may also be cleaned with isopropyl
alcohol. After this type of thorough cleaning, the post
and tube should be treated with a light coating of
machine oil to protect the surfaces against corrosion
and to ensure smooth operation.
Tensioner Installation
Remove the button head screw and washer located at
the end of the tensioner bar with the 3 mm hex wrench
provided. Slide the tensioner onto the bar, being careful
to align the bar with all of the bearings and the drive gear
with the gear track. Replace the button head screw and
washer in the end of the tensioner bar.
Crank Arm Installation
Remove the flat head screw located on the crank shaft
with the 2.5mm wrench provided. Slide the crank handle
over the crank shaft while aligning the holes. Replace
the flathead screw.