FAULT
CAUSE
F08
Heater relay stuck on or
pressure switch stuck on full.
LED 4
ON
F09
Machine set up error.
LEDs
1 & 4
ON
F10
No fill or empty signal from
LEDs
pressure switch.
2 & 4
ON
F11
Drain pump disconnected.
LEDs
1, 2 &
4 ON
F12
No communication between
the display board and the
LEDs
module.
3 & 4
ON
F17
No supply to door lock or door
LEDs
open.
1 & 5
ON
F18
Communication error
between microprocessor and
LEDs
DSP (Digital Signal
2 & 5
Processor).
ON
Service Manual UK
CORRECTIVE ACTIONS
-
Check wiring to heater and continuity of wash element
(25Ω);
-
Check pressure switch connections and correct pressure
switch operation;
-
Check edge connector J3 has secure connections on
module;
-
High level of ambient humidity / condensation may cause
this fault.
-
Check if module has soldered Eeprom, replace module and
Eeprom;
-
Check if module has a plug-in Eeprom, check Eeprom is
correctly connected to socket on module;
-
Check edge connector J3 has secure connections on
module;
-
Remove edge connector J3 on module check wiring and
contacts at position 1, 2, 3 and 4 on pressure switch;
-
Check that the pump connection plug is connected;
-
Check edge connector J9 has secure connections on
module;
-
Remove edge connector J9 on module check wiring and
contacts at positions 8 and 9 on connector J9;
-
Check edge connector J11 has secure connections on
module;
-
Check edge connector J11 / 5 way connector of display
PCB;
-
Remove edge connector J11 on module check wiring and
contacts;
-
Remove edge connector on display module check wiring
and contacts;
-
Check door is closed and latched correctly;
-
Check edge connector J4 has a secure connection on
module;
-
Remove edge connector on module J4 and check wiring
and contacts on all connections.
-
Renew module.