Dimplex BLF74 Wartungshandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Wartungshandbuch für Innenkamin Dimplex BLF74 herunter. Dimplex BLF74 16 Seiten. Section 10309 manufactured electric fireplaces
Auch für Dimplex BLF74: Benutzerhandbuch (3 seiten)

Dimplex BLF74 Wartungshandbuch
7. Remove the 2 screws, that secure the cover panel
(Figure 13), located at the top of the mirror on the left
side of the unit.
8. Remove the two screws on either side of the heater/
blower assembly and gently lower the assembly so that
the top can be viewed.
CAUTION: When removing the blower assembly
mounting screws, support the assembly to prevent any
damage to the unit.
9. Remove the 6 screws (3 sets) that secure the blower to
the assembly (Figure 14).
10. Disconnect the wiring connections noting their original
locations.
!
NOTE: Using a flat head screwdriver gently pry
between the end of the connectors and the blower/fan to
release the wires.
11. Properly orient the new blower/fan assembly and con-
nect all of the wiring connections.
12. Reassemble in the reverse order as above.
14
Figure 14
Mounting Screws
www.dimplex.com