Attach Tank Lines

Step 6 – Attach Drain Line to Fleck Meter
Step 7 – Connect Brine Line to Fleck Meter
Step 8 – Connect Brine Well to Tank Side Wall
1. Wrap threaded connection point with 3-4
wraps of Teflon tape. Install provided plastic
barbed fitting.
2. Install drain line (not included) to barbed
fitting (found on Fleck valve) with a stainless
hose clamp (not included). Drain line should
extend to a main drain to dispose of waste
water.
1. Prep brine line prior to install using brass
nut, plastic Ferrule & brass tube insert.
2. Connect provided brass nut to the Fleck
valve. Be careful not to overtighten. Over-
tightening will cause damage.
1. Locate predrilled hole in brine tank. Fas-
ten brine well to side wall of brine tank using
the white overflow elbow & plastic nut.
* This is preinstalled on Space Saver version.