6. After rebooting, reconnect with the Yamaha device, then click the Transmit tab in the Device
View window, and click the Create a New Multicast Flow button.
7. In the Create Multicast Flow pop-up screen, click (to check) in the AES67 Flow box, then
select the first eight channels, and click the Create button.
A multicast flow is now listed in the Transmit Flows pane of the Transmit window. This
specifies that audio received on analog channel 1 from the cinema sound processor is routed
out of digital channel 1 of the Yamaha device, channel 2 is routed out of digital channel 2, and
so on. You have now completed the AES67 setup in the Dante Controller software.
8. Connect the Yamaha Tio1608-D Primary Ethernet port directly to the amplifier DOLBY
ATMOS CONNECT IN port.
Dolby CP750 7.1 audio for the Dolby Multichannel Amplifier Installation Manual
7 May 2018 Issue 1
Setting up the system
12