ELECTRICAL CONNECTIONS
3. Motor (terminal block X4)
Connect the motor to terminals "U", "V" and "W".
380V motor: max. operating current < 9 A, wattage ≤ 4 kW.
3~Motor: 380 V
4. Limit switches (terminal block X0)
Connect limit switch wires "OP" (opening switch), "CL" (closing switch) and "GND" (common wire).
Close Open Common
5. 3-position control post or key-switch (N.O. contact) (terminal block X1 and X2)
Connect 3-position control post to the terminals "OPEN", "STOP", "CLOSE" and "GND".
Connect the key-switch to terminals "D" and "GND".
Key-switch
3-position control post
Трехпозиционный
WARNING! If 3-position control post is not used, install a jumper between "STOP" and "GND".