SET
30
3 sec
Press and hold SET key for 4 seconds until the Parameter Window displays "LCK".
Release the SET. The display will show "0". Use "+" and "-" keys to adjust the display to
155 (another pass code) and press SET.
Setting the calibration offset. The parameter window will first show "SC "for a second
and then its value, Use "+" and "-" keys to change the setting. When finished, press the
SET again to confirm the change. For example, if the temperature is 1 ° C too high during
calibration then use "-" to set the value to -1 to offset value.
Setting the output percentage. The parameter window will first show "OUt "for a
second and then its value, Use "+" and "-" keys to change OUt value to your desired limit
value and press SET.
Setting Celsius (C) or Fahrenheit (F). When SET is pressed, the display will show "C-
F" and then its value of either "C" or "F". Press "-" for C or "+" for F.
LC8
155
Figure 8. Code 155 Parameter setup flow chart
SET
sc
SET
al
SET
fa
SET
oAL
SET
hy
SET
Cool
SET
00t
SET
C-F
SET
C8
SET
14
0
SET
250
SET
0
SET
0
SET
3
SET
0
SET
100
SET
F
SET
1
SET