Duratech DLC-010 Manual - Página 9
Navegue en línea o descargue pdf Manual para Controlador Duratech DLC-010. Duratech DLC-010 11 páginas.
Troubleshooting
PROBLEM
CHECK
Cover does not close
Status LED is OFF
Status LED is RED
Status LED is blinking RED
Check motor connections
Cover stops at an
incorrect position
Cover moves in the
wrong direction
Check the motor sensor
Calibration failed
feedback
Remote calibration
Check DIP switch 1 position
can not be started
Check CAN LED
Declaraction of Conformity
Declarations of conformity covering this product are available for
download from the House of Duratech website: www.duratech.be
16
SOLUTION
Check power to DLC-010
Cool down the device, restart and
try again
Contact customer support
Restart calibration or calibration
correction
Swap the 2 motor connections or
swap motor control via LinkTouch
(settings menu --> Cover settings)
DIP switch 1 must be ON
Fix the CAN wiring