TROUBLESHOOTING
WARNING:
Only qualified maintenance personnel should attempt the following procedures:
Problem
Possible Cause
Main Line Circuit Breaker
tripped.
Improperly fastened
Connections.
Fuses for Motor
Controller blown.
Conveyor Not
Operating
Belt is hung up.
Tension too low on Belt
(Power Switch lights and
Motor turns but Belt does
not move).
Belt Tracks to
Belt Adjustment Screws
One Side
are out of position.
SPARE/REPLACEMENT PARTS
Part #
Part Description
40671
Conveyor Belt Guide
39376
18" Metal Halide Bulb (standard)
39613
18" Mercury Bulb
40672
Reflector for 18" Conveyor
39661
Conveyor Belt for 18" Conveyor
39373
25" Metal Halide Bulb (standard)
39614
25" Mercury Bulb
40673
Reflector for 25" Conveyor
39663
Conveyor Belt for 25" Conveyor
Dymax WIDECURE UV Conveyor
Testing
Toggle Power Switch off,
then on.
Check all connections.
Remove Fuses from Fuse
Holders (located in the left side
of control box of unit) and
check with an Ohmmeter.
Inspect the Belt for any signs
of a mechanical bind.
Verify the operation of the
Drive Shaft and Drive Rollers.
Visually inspect the Belt. The
Belt will track to one side.
Corrective Action
Find cause of tripped breaker.
Properly fasten connections.
Replace Fuses if defective.
Resolve bind and continue
operation.
Use the tracking adjustment
screws to increase the tension
on the Belt. Both knobs need to
be turned the same amount to
maintain alignment.
Tighten the Belt Adjustment
Screw (the one located on the
side to which the Belt is
tracking towards) until Belt
tracks straight. Only minor
adjustments should be made at
one time.
13